Loans for cold storage warehouses

A cold store is underwritten as a refrigeration machine on pallet revenue. Lenders read positions, turns and power cost, then discount the building for reuse. SBA treats a facility with more than 50% of total square footage equipped for refrigeration as special purpose, which pushes the 504 structure to 50% bank, 35% CDC, 15% borrower. Ammonia systems holding 10,000 pounds in a process or more fall under federal risk programs.

Updated . Rates refresh every business day.

CMBS industrial delinquency, all industrial (Trepp, September 2026)1.14%8
SBA 504 structure for special purpose property50% bank, 35% CDC, 15% borrower1
Federal supervisory ceiling for bank construction loans80% maximum LTV for commercial, multifamily and other nonresidential construction5

Programs that lend on it

Not ranked by price: only some of these programs have a published spread that applies here.

ProgramIndicative rate Leverage benchmark Min DSCR Recourse
Owner-occupied commercial mortgage (SBA 504, 7(a), bank) Deal by deal Set deal by deal 1.15x1 Full recourse
Bank commercial mortgage Deal by deal 85%5 (bank supervisory ceiling) Not published Full recourse
Life insurance company loan 6.09 to 7.14% Set deal by deal Not published Non-recourse (standard carve-outs)
Commercial construction loan Deal by deal Set deal by deal Not published Full recourse
Commercial bridge loans Deal by deal, this index does not cover this asset Set deal by deal Not published Deal by deal
Debt fund and mortgage REIT loans Deal by deal, this index does not cover this asset Set deal by deal Not published Deal by deal
Hard money and private commercial loans Deal by deal Set deal by deal Not published Full recourse
Indicative rates are today's index plus each program's published spread; not quotes. No listed program publishes a maximum LTV for this property type, so the leverage column shows a labeled benchmark where one exists.

Layers that can sit on or around the senior loan here: C-PACE.

Programs that are out or unconfirmed

Fannie Mae, Freddie Mac and FHA multifamily loansResidential rental programs only.

National data: cold storage warehouses

SBA 7(a) loans, FY2022 to FY2026

Loans to operating businesses under NAICS 493120, not investor loans. Real estate financed under SBA must be owner-occupied, and a 7(a) loan may fund working capital or equipment instead. FY2026 runs through June 30, 2026.

Loans approved16
Total approved$23.9 million
Median loan$805,000
Middle half of loans$186,000 to $2,478,000
Median term120 months (10 years)
Loans of 20 years or more (these generally carry real estate)5 (31.2%)
Median size of those loans$2,304,000
Startups (two years old or less)50.0%

SBA 504 loans, FY2022 to FY2026

Owner-occupied projects only. Amounts are the SBA-backed second lien.

Loans approved11
Total SBA-backed debentures$37.4 million
Median debenture$3,402,000
Middle half of debentures$2,367,500 to $4,999,500
Median first-lien bank loan alongside it$6,147,890
Median term300 months (25 years)
Charged off, among resolved loans (approvals FY2010 onward)0.0% of 26

Source: SBA 7(a) and 504 FOIA loan files, as of June 30, 2026. Charge-off shares exclude active loans and are not default rates.

Businesses in this industry

Employer establishments1,367
States and DC reporting44

Source: Census County Business Patterns, 2023. Counts operating businesses with employees, not buildings.

The building is the smaller part of the asset

A dry warehouse is a shell with a floor. A cold store is an insulated envelope built around a refrigeration plant, and its cost, its income and its failure modes all come from that plant. Underwriters start by asking which of three businesses they are looking at.

Facility type Revenue Credit question Likely source
Public refrigerated warehouse (operator stores for many customers) Storage and handling fees Pallet occupancy, customer churn, power Bank, debt fund for growth
Private facility owned by a food company No outside revenue; the company’s own balance sheet The company’s cash flow Owner-occupied, SBA if eligible
Net leased to one operator Rent Tenant credit, lease length, who owns the plant Life company, bank
New automated freezer None yet Pre-lease, technology, cost Construction, debt fund
Older cooler being re-skinned Partial or none Rebuild cost, conversions Bridge, hard money

The operating metric: pallet positions and turns

The unit is a pallet position, and the revenue has two parts that behave very differently.

Storage revenue is pallets on hand times a rate per position per month. Occupancy here means pallets held divided by racked positions. Facilities are seasonal, so a single month proves nothing. Lenders want average occupancy through the full harvest and holiday cycle.

Handling revenue comes from each pallet moved in and out, plus services such as blast freezing, case picking, cross-docking, repacking and transportation. A facility with fast turns earns much more per position, and it also spends more on labor.

The questions a lender asks:

  • Positions by temperature zone. Freezer, cooler, ambient and blast each rent differently.
  • Turns per pallet per year. Slow turns mean storage-driven income that holds up in a downturn and earns less. Fast turns mean more labor and margin risk.
  • Customer concentration. The share of revenue from the top few customers, and whether they hold contracts or take space month to month.
  • Committed versus spot. Reserved space with minimum billing is valued more than pallets that arrive when capacity is tight elsewhere.
  • Power cost per position. Often one of the top expense lines. Lenders want the utility tariff, the demand charges and any time-of-use exposure, and they will ask whether the contract rate is about to reset.
  • Labor. The freezer environment means higher turnover. The plan for a wage increase matters more than today’s wage.

Lenders haircut value-added services more than storage. Some treat transportation brokerage as outside income and leave it out.

The refrigeration plant is a capital line

A lender wants the plant inspected by someone other than the seller’s maintenance contractor, with a remaining-life opinion on these components.

Component What can go wrong Financial consequence
Compressors and condensers Age, rebuild history, parts availability Six- and seven-figure replacement, sometimes during a heat wave
Evaporators and controls Frost management, efficiency Higher power use and product risk
Insulated panels and vapor barrier Moisture entering the panel joints; ice buildup Slow decline in efficiency, then panel replacement
Floor and under-floor heating Failure lets frost push up the slab, called frost heave Often the most expensive single repair in the building; racking must come out
Backup power Absent or undersized Product loss claims when the grid goes down

Frost heave deserves a separate question. A freezer floor without working heat beneath it can freeze the ground, lift the slab and break the racking grid. Ask for sensor readings over time. A buyer of an older freezer should get an engineering report that addresses this directly.

Replacement reserves on the loan should reflect the plant, not a standard per-square-foot reserve. Ask how the lender plans to size them. C-PACE can fund qualifying refrigeration and envelope upgrades in states with active programs and with senior lender consent, and it suits this kind of equipment-heavy work better than most building types.

Ammonia, refrigerants and permits

This is where cold storage differs most from other industrial assets.

  • EPA Risk Management Program. A facility holding anhydrous ammonia above 10,000 pounds in a process2 must have a risk management plan on file under 40 CFR Part 68.
  • OSHA Process Safety Management. The same chemical at 10,000 pounds3 brings process safety requirements, including hazard analysis and mechanical integrity programs.
  • Emergency planning and inventory reporting. Facilities holding regulated quantities generally have community right-to-know duties under EPCRA, even below the thresholds above. Confirm with the environmental consultant.
  • New synthetic systems. EPA’s May 2026 Technology Transitions rule set an interim limit of 700 global warming potential, tightening to 150 or 300 from January 1, 2032. The limit applies by installation date, so an existing plant is not forced out by it, though a major retrofit may be analyzed differently.
  • Food safety. A facility holding food for consumption generally must register with FDA. Lenders ask for inspection history and for third-party audit scores if the customers require them.
  • Phase I. Lenders normally require it. Old ammonia releases, buried lines and past fuel storage for yard equipment are typical items. Refrigerated warehousing by NAICS is not on the SBA’s environmentally sensitive list, but prior uses are checked independently, and the SBA investigation still follows loan-size rules.

A facility without a current RMP or PSM program is not only a compliance issue: it is a sale and insurance problem. Lenders treat it as a condition to close.

Programs: who says yes

Program Fit Limits
SBA 504 through an owner-occupied lender Owner-operators buying or building Must occupy at least 51% of rentable space; 50% bank, 35% CDC, 15% borrower if special purpose; 50% bank, 30% CDC, 20% borrower if also a new business
SBA 7(a) Operator buying a business with the building $5,000,0001 cap
Bank Most mid-sized operators Looks at the operator’s cash flow first
Life company Long-term net lease to a strong operator Selective on secondary markets and special use
Construction New builds, usually pre-leased Supervisory ceiling 80% maximum LTV for commercial, multifamily and other nonresidential construction, and the HVCRE capital rule at 15% of appraised as-completed value for bank-held loans
Debt fund Expansions, automation and portfolio plays Cost
Agency and FHA Do not apply Multifamily and healthcare only

The SBA figures in the data section cover owner-occupying businesses only. The count is low because most cold storage is owned by large operators or institutional investors who do not qualify.

Food-related operators should also look at the SBA fee relief for FY 2027, which covers some food supply chain businesses: SBA's upfront and annual 504 fees are waived in FY 2027 for manufacturers (NAICS 31-33), designated food supply chain industries and businesses in rural areas. Whether a given refrigerated warehouse is a designated food supply chain industry turns on the NAICS code and the SBA notice, so confirm with the lender.

Automation changes the underwriting

A highly automated freezer, with cranes or shuttles running in a tall racked structure, cuts labor and packs more pallets per foot of building. It also ties the facility to a software and parts vendor and may make the racking part of the structure. Lenders treat that system as equipment with a finite life even when it holds up the roof. They ask for a service contract, spare parts plan and an engineer’s estimate of the cost to keep it running. Reuse is the harder question: a rack-supported building has no value as a conventional warehouse once the rack is gone.

What it is worth to the next owner

Three values exist, and they can be far apart.

Value Basis Reliability
Going concern Operating cash flow from storage and handling Depends on the customers staying
Leased fee Rent from an operator on a long lease Depends on the tenant’s credit and its need for this location
Real estate, if vacant Dry warehouse value less the cost of decommissioning The lender’s floor

An appraiser should allocate between real property, refrigeration equipment and business value. The allocation matters for three reasons: bank loans secured by real estate depend on the real property portion, SBA projects are structured against what is being purchased, and equipment that an appraiser classes as a fixture still wears out faster than a building.

Reuse: insulated buildings can go to ambient or food-grade tenants. Ceiling height, door count and panel condition decide whether anyone wants them. Demand for quality cold space is tied to food distribution, so strong locations near population centers, ports and rail attract replacement operators. A low-clear-height building from another era is a candidate for demolition.

Illustration: pallets into a loan

An illustration, not a quote, using assumed numbers. A public refrigerated warehouse has 20,000 pallet positions and averages 82% occupancy, or 16,400 pallets. Storage at $19 per position per month earns $3,739,200. Handling at 8 turns and $16 per turn earns $2,099,200. Total revenue is $5,838,400. Labor is $1,950,000, power $640,000, and other operating costs $830,000. Cash flow is $2,418,400.

The lender deducts $200,000 a year for refrigeration capital. Assume a 1.35x DSCR on a 25-year schedule at 7.00% (loan constant 8.48%), and an appraised real estate value of $19,000,000 tested at 65% LTV.

Test Loan
Cash flow test: ($2,418,400 less $200,000) / 1.35 / 8.48% $19,375,000
Real estate test: 65% of $19,000,000 $12,350,000
Loan offered $12,350,000

Cash flow supports far more debt than the real estate does. That gap is why operators with strong cash flow often ask about a blended structure, and why lenders treat equipment value with care. Occupancy also has more leverage than it looks. Ten points of occupancy on these assumptions removes 2,000 pallets and $712,000 of revenue, while much of the power bill and the fixed labor remain. Run the debt yield side in the debt yield calculator.

Red flags

  • Occupancy reported at the peak season only.
  • One customer holding most positions on a short or month-to-month agreement.
  • A freezer floor with no recorded under-floor temperature history.
  • RMP or PSM paperwork that has lapsed, or no process hazard analysis on file.
  • Power on a contract about to reset, with no sensitivity analysis.
  • An equipment list that the seller calls included but the appraisal treats as personal property.
  • Pro forma rates set against a competitor’s newly built automated facility.
  • A sale-leaseback rent set by the operator’s need for cash, not by the market.

Documents to assemble

  • Monthly pallet count and revenue by storage, handling and services, by zone
  • Customer list with contract terms and top-ten revenue share
  • Utility bills, tariff and any power contract
  • Refrigeration engineer’s report, panel survey, floor heat data and maintenance logs
  • RMP filing, PSM records, inspection history and any release reports
  • FDA registration and food safety audit results
  • Appraisal with allocation among real estate, equipment and business value
  • Phase I, survey, title and zoning letter
  • Insurance schedule covering product spoilage and pollution
  • Tax returns, financial statements and business plan

Need terms on a facility? Get a quote and send the monthly pallet report with it; it saves a round of questions.

Similar property types

All property types

Questions people ask

Does a cold storage building count as a special use property for SBA?

It does when more than 50% of total square footage equipped for refrigeration. Below that line the same building can go through 504 on the standard structure of 50% bank first lien, 40% CDC debenture, 10% borrower. Measure before you structure the deal. A partly refrigerated distribution warehouse often falls under the line.

Are refrigerants a financing issue now?

They can be for new systems. In May 2026 EPA set an interim limit of 700 global warming potential, tightening to 150 or 300 from January 1, 2032 for new cold storage warehouse systems. Buyers and lenders ask what refrigerant the plant uses and whether any planned replacement would meet the limit that applies on the installation date.

Can an investor use a CMBS loan on a cold store?

It is uncommon. Cold storage inside securitized pools is hard to isolate in public filings, and we do not track a separate delinquency figure. A stabilized asset leased to a large operator is more likely to see a life company or bank than a conduit.

Sources

  1. SBA SOP 50 10 8.1, as of October 1, 2026
  2. 40 CFR 68.130, eCFR, as of November 4, 2026
  3. 29 CFR 1910.119 Appendix A, eCFR, as of November 4, 2026
  4. EPA final rule, 91 FR (May 26, 2026), Federal Register, as of May 26, 2026
  5. eCFR, 12 CFR Part 365 Appendix A (Interagency Guidelines for Real Estate Lending Policies), as of November 26, 2021
  6. 12 CFR 324.2, definition of HVCRE exposure (eCFR), as of October 29, 2026
  7. SBA Information Notice 5000-881796, 504 Fees for Fiscal Year 2027, as of October 1, 2026
  8. Trepp, CMBS Delinquency Report, September 2026 (Oct 2, 2026), as of September 30, 2026
  9. 40 CFR Part 68, Chemical Accident Prevention (Risk Management Program), as of November 2026
  10. FDA food facility registration, 21 CFR Part 1 Subpart H, as of November 2026
  11. SBA 7(a) and 504 FOIA loan files, as of June 30, 2026
  12. Census County Business Patterns, as of 2023

How we check figures: methodology and editorial policy.

Get financing for this deal

Send the property and the loan once. A person at Janover Capital LLC reads it, tells you which programs fit and replies, usually within one business day.

Get financing